Guarding is the part of a machine project that gets approved quickly and costs money later. Three decisions made too early cause most of the rework: the window material, the mesh size, and how the door interlocks. Get those right and the rest is straightforward sheet metal.
1. Classify the guard before you quote it
Ask one question: if a hand reaches the object behind this panel, can it be injured? If yes, the guard is a safety device. If no, it is a process or environmental cover and the rules are much looser.
| Type | Governing reference | Key criteria | Typical failure |
|---|---|---|---|
| Safety guard: laser housing, robot fence | ISO 12100, ISO 14120, EN 60825-4 | Impact resistance, opening size, interlock reliability | Mesh too coarse; switch knocked out of alignment |
| Process cover: dust, spatter, acoustic | Plant and process requirements | Sealing, 10–25 dB(A) noise reduction | Dust build-up; window hazing |
| Environmental cover: outdoor, coastal | IEC 60529, ISO 12944 | IP rating, corrosion life, temperature | Corrosion, condensation, gasket ageing |
Once it is a safety device, two rules follow. No casual modification: an extra cable hole, PC swapped for acrylic, a fixed panel turned removable — each changes a safety function and needs re-assessment on record. And a clear scope split: we fabricate panels, frames and windows and assemble them; machine safety category, interlock logic and the CE declaration stay with the integrator.
2. Laser housings: optical density first
OD = log₁₀ ( H₀ / MPE ), where H₀ is incident radiant exposure or irradiance at the window and MPE is the maximum permissible exposure for that wavelength and pulse duration. Transmittance T = 10⁻ᴼᴰ.
Worked example: a 1064 nm fibre laser at 2000 W striking the inside of an observation window. At OD 5, transmittance is 10⁻⁵ and no more than 0.02 W passes. At OD 4 the figure is 0.2 W — enough to damage a retina at close range. So "laser-safe window" on a drawing means nothing. Ask which wavelength, continuous or pulsed, what OD, certified by whom.
- OD is wavelength-specific — one filter can be OD 6 at 1064 nm and OD 2 at 532 nm. Multi-wavelength equipment, including 650 nm aiming beams, must be sized on the worst case.
- Pulsed sources are rated on peak — Q-switched and ultrafast lasers reach peak power densities orders of magnitude above average power, so an OD derived from average power is meaningless.
- Seams leak — a 3 mm panel gap, a hinge line, a cable entry. Matt dark interiors cut diffuse reflection; add a light-trap fold at door edges.
- Keep the window small — 300×400 mm covers most load and unload needs. Class 4 equipment also needs perimeter warning and interlocked beam stop, which belongs to machine design.
3. Window material: acrylic, polycarbonate or glass
| Material | Impact | Chemical | Best for |
|---|---|---|---|
| PMMA, 92% transmission | Medium, brittle | Poor; acetone and alcohols craze it | General viewing, low-cost covers |
| Polycarbonate, 88–90% | High, no shatter | Fair; alkaline and solvents stress-crack it | Robot fence windows, spatter guards |
| Laminated glass, 85–90% | Medium, holds on break | Excellent | Frequent cleaning, chemicals |
Most failures are polycarbonate installation stress, not the sheet. Hole clearance of 1–2 mm or slotted holes: PC expands about 0.065 mm/(m·K), so a 1 m panel through a 40 K swing needs 2.6 mm, and a rigidly clamped panel star-cracks at the fasteners. Torque 0.6–1.0 N·m with resilient washers, strip 12–15 mm wide. Never clean with acetone, thinners or alkaline detergent — neutral detergent and a soft cloth only, or the cleaning crew destroys the window in a week. Chamfer cut edges 0.5 mm to remove micro-crack initiation sites.
Laser filter acrylic is different: the absorber is in the sheet, so it degrades with cumulative exposure. Suppliers quote a dose or replacement interval, and heat accelerates ageing. Log the change — a filter never replaced has silently failed.
4. Robot fences: work back from the hazard
Mesh size is not a style choice; it sets how far a hand reaches through. In ISO 13857 a smaller opening shortens the reach, so the fence can stand closer. Open the mesh and the arm, then the shoulder, enters — and the required distance jumps to 850 mm.
- Up to 8 mm opening — 20 mm minimum distance, fingertips only. Fine mesh for small cells; the 20×20 mm welded mesh band below is the practical default for most robot cells.
- 8 to 20 mm opening — 120 mm minimum, a whole hand fits through. This is the 20×20 mm welded mesh band and the practical default, with 150 mm clear to the hazard to absorb build tolerance and door sag.
- Above 20 mm — the arm passes, so the distance jumps to 850 mm. That is why 40×40 and 50×50 mm mesh should never be specified alone on a tight line; where coarse mesh is needed for airflow, line it with 20×20 or a solid inner panel.
- Height and floor gap — fence from 1400 mm, 1800 mm with top mesh where anything can be climbed; floor gap 20 mm maximum or a kick plate, because a 100 mm gap voids the whole mesh calculation.
- Light curtains are a different method — with a curtain or safety scanner, minimum distance comes from ISO 13855 using approach speed and total stop time. Do not reuse the mesh table.
5. Frame and panel: extrusion or folded steel
- Aluminium extrusion, 40×40 or 45×45 — no welding, demountable, ±0.3 mm length tolerance, modifications cost only new profile and brackets. Good to about 2 m and for export where the guard ships flat. Weaker against side impact; T-nut joints need 8–10 N·m and fresh nuts after three re-assemblies.
- Folded steel, 1.5–2.5 mm — stiffer, impact resistant, takes curved and irregular shapes, lower unit cost. Welding distortion must be straightened or the door hangs crooked; local paint damage is hard to touch up; volume drives freight.
- Hybrid, most of what we build — extrusion frame and window aperture, steel skirt and top panels, PC glazing. Demountable and impact resistant at once.
Values worth copying: PC at 6 mm minimum over an 800 mm window span, 8 mm or a centre mullion over 1200 mm; posts at 1200 mm centres; three hinges above 900 mm door width; gas strut above 25 kg door weight. None are code values — they are the numbers that stop callbacks.
6. Interlocked doors: the mechanical details
Interlock failures are rarely electrical. They are a door that sagged 1 mm, a bracket knocked 2 mm out of line, an actuator gap out of tolerance. The machine then believes a door is closed when it is not.
- Match the device to the risk — ISO 14119 distinguishes interlock designs, and coded, defeat-resistant types belong on high-risk doors. The input is the required performance level; PL d generally means dual channel with diagnostics.
- Lock direction follows the risk — power-to-unlock springs open so a trapped person can get out; power-to-lock holds the door until the hazard is gone, which is what inertia or long cool-down demand.
- Mounting flatness 0.5 mm — switches and actuators sit on sheet metal, and sheet metal deflects. Slotted brackets with ±3 mm adjustment, locked after commissioning.
- Add a door stop — one hit from a trolley moves the switch and the interlock is gone. Take the impact on a frame-side stop.
- No bypass, no shared route — maintenance by key switch with a timer, not "hold this button to open"; the switch cable gets its own gland and 150 mm slack.
7. Build, pack, install and RFQ
- Keep panels within 2400×1200 mm — it suits crates, forklifts and lifts. Number every panel, ship an assembly drawing and bolt list, dowel the critical joints.
- Sea freight: ISPM 15 crate with IPPC mark, VCI film and desiccant inside; for Southeast Asia and Gulf projects we switch hardware to zinc-plated or stainless as standard. Adjustable feet at ±15 mm travel beat shimming on an uneven floor.
- Put window material, thickness and OD in the RFQ, plus mesh size, clear distance, fence height, interlock type and required PL, colour reference, film thickness 60–80 μm, and the panel split with crate size.
Acceptance carries numbers too: diagonal within 2 mm/m, door gap 2 ± 1 mm, door-to-frame flatness within 1 mm, window free of scratches and bubbles, laser windows with certification and OD label, interlock triggering at the correct position, plus a document pack with material certs and test record.
Cost structure differs from a standard enclosure because glazing dominates: sheet and profile 35–45%, window 15–25% (laser filter can exceed 30%), coating 10–15%, hardware and interlock 10–20%, labour around 15%. The cheapest lever is window area, then profile size, and panel thickness last. Lead time is 7–15 days including window procurement, samples in 5–7 days, plus three days for interlock commissioning.
8. FAQ
Does every guard need an interlocked door?
Only if the risk assessment says so. Where a hand can still reach moving parts, a laser path or a hot surface after the door opens, interlocking is required. Where the door only covers protected low-voltage terminals, a tool-operated fixed panel is simpler.
Can standard acrylic replace a laser window?
No. Standard acrylic is almost transparent at 1064 nm and provides no protection. A laser window must be rated for the actual wavelength and mode, with OD certification from the supplier.
Is 20×20 mm mesh enough for a robot fence?
Yes, provided clear distance to the hazard is at least 120 mm, fence height at least 1400 mm and floor gap 20 mm or less. Miss one and the mesh calculation no longer holds.
Extrusion or folded steel for the frame?
Extrusion up to about 2 m where the guard ships flat or will be modified. Folded steel where impact resistance or curved shapes matter. Most guards we build are hybrid: extrusion frame, steel skirt and top panels.
Why do polycarbonate windows keep cracking?
Almost never the sheet. Check hole clearance of 1–2 mm, torque of 0.6–1.0 N·m with resilient washers, and whether acetone or alkaline cleaner was used.
How are export orders packed?
Panels split to stay within 2400×1200 mm, crated to ISPM 15 with the IPPC mark, shipped with VCI film and desiccant, hardware zinc-plated or stainless.
Xingyuan Electric (Suzhou) Co., Ltd. builds sheet metal enclosures and structural parts with a 30+-person team and a 3000㎡ plant equipped with 20+ laser cutting, CNC bending and welding machines. Machine guards, laser housings, robot fences and interlocked doors are routine work: drawing review, glazing advice, bending, welding, coating, assembly and export packing all happen in-house. Standard lead time is 7–15 days, custom work from drawing or sample is welcome, and English drawing communication is available for export projects. Send enquiries to sale@xingyuanep.com.