Xingyuan Electric provides standard 19-inch cabinets and customized rack solutions for data centers, enterprise IT rooms and edge computing — covering server cabinets (42U), network cabinets, open racks, wall-mount network racks, outdoor cabinets and column (power distribution) cabinets. All series are EIA-310-D / IEC 60297 compatible, with ventilation, cable management, PDU integration and EMC protection, and support drawing-based OEM/ODM custom in both prototype and batch quantities.
Get a data center cabinet quote →A data center cabinet is a standard mounting frame for centrally installing servers, switches, storage and network equipment. The mainstream is 19-inch (482.6mm) wide with height measured in “U” (1U = 44.45mm). Beyond carrying equipment, it must handle cooling/ventilation, cable management, power (PDU), grounding and safety — the infrastructure of any IDC or server room.
From standard server cabinets to industry-specific racks, covering every data-center scenario. Click for product details.
| Item | Range | Note |
|---|---|---|
| Mount standard | 19-inch (482.6mm), EIA-310-D / IEC 60297 compatible | Square/round hole rails |
| Height | 18U / 22U / 27U / 32U / 37U / 42U etc. | 1U = 44.45mm |
| Material/thickness | SPCC cold-rolled steel, post 1.5–2.0mm, door 1.2–1.5mm | Powder-coated finish |
| Load | Static 800–1500kg | Frame & plinth dependent |
| Protection/vent | Indoor IP20, front/rear mesh doors ≥70% open | Single/double door |
| Power/cable | Optional PDU, cable manager, tray, ground bar | ODM integration |
| Item | Xingyuan | Brand standard |
|---|---|---|
| Standard | 19-inch universal, square-hole rails | Same standard |
| Price | 40%–60% below brand cabinets | Brand baseline |
| Lead time | 7–20 days, expeditable | Brand often weeks |
| Custom flexibility | U/size/color/acc/silk-screen editable | Mostly standard |
| Min. order | Prototype 1 / batch from 10 | Channel stock |
| ODM integration | PDU/cable/fan pre-installed | Bought separately |
Beyond standard cabinets, we accept OEM/ODM custom for data-center cabinets: adjust U-count/height/depth, custom color & silk-screen, pre-install PDU and cable managers, add fans/AC/side panels, EMC shielding and grounding design. Prototype and batch supported; drawings under NDA.
Cabinet power is central to reliable data-center operation. Xingyuan supplies PDUs from basic to intelligent, with ODM pre-installation: select by device wattage and cabinet density, support CN/IEC/industrial plug input, multi-standard outlets, surge & overload protection, optional metering/remote-switch/environment monitoring, with cable trays and ground bar for a complete power chain.
| Item | Range | Note |
|---|---|---|
| Basic PDU | Fixed outlets, unmanaged, general server/network | Cost-effective |
| Metered PDU | Current/power display, visible load | Capacity planning |
| Intelligent/Switched PDU | Remote switch + env. monitoring, per-port control | High-density/remote O&M |
| Zero-U vertical PDU | Mounts on cabinet side, saves U space | High-density choice |
| Input/protection | CN/IEC/industrial plug, surge + overload | ODM pre-installed |
19-inch (482.6mm) is the mounting width defined by IEC 60297 / EIA-310-D, ensuring universal hole patterns across servers, switches and other gear for standardized, mixed-brand deployment.
1U = 44.45mm, so 42U can hold ~42 1U devices (reserve space for switches, cabling, PDU). Typical mixed server+network+PDU leaves 10–20% for cooling.
Our cabinets use 9/16-fold profile frames with 800–1500kg static load. For very heavy units, floor-mount with adjustable plinth/load plate; share weights and we help select.
Front/rear mesh doors (≥70% open) + top fan unit create front-to-back airflow; high-density can add side vents, AC or hot/cold aisle isolation — we advise per thermal load.
Yes. 19-inch square/round rails, PDUs, cable managers and shelves follow the universal standard and work with off-the-shelf parts; we can ODM pre-integrate if needed.
Prototype from 1 unit; batch from 10. Standard 7–20 days; custom/ODM per complexity, expeditable.
By wattage and density: basic PDU (fixed outlets) for ordinary gear; metered/switched PDU for metering or remote switching; zero-U vertical PDU to save space in high-density cabinets. Input can be CN/IEC/industrial plug — we ODM pre-install.
For high density (single cabinet >5kW) we recommend hot/cold aisle isolation with containment units + blanking panels to avoid hot/cold short-circuit and raise AC efficiency by 30%+. For mid/low density, front/rear mesh doors + good cabling suffice.
Send your equipment list/drawings with quantity and environment; we return a proposal and quote within 24–48 hours, with prototype and batch support.